31.5.10.3 Initial Output Frequency - Acceleration/Deceleration Pulse Output (LT Series)

This function sets the output frequency for when the pulse output starts and stops. You can use 0 and 10Hz to 65kHz for setting the initial output frequency.

Set Up Process in GP-Pro EX

From the [Project] menu, point to [System Settings] and click [I/O Driver]. On the [Int.Driver 1] tab, click [Pulse Settings].

Specify the [Initial Output Frequency] in the [Pulse Settings] dialog box.

  1. From the [Project] menu, point to [System Settings] and click [I/O Driver]. Select [PLS] in [Function].

  2. Set the initial output frequency in the [Initial Output Frequency].

Set Up Process with System Variables

Define the initial output frequency in the system variable (#L_PLS*_SHZ). The system variable name adjusts to match the CH pulse output to which it's mapped.