31.7.11.5 Object 2103h: Analog Input Upper Limit

This object stores the maximum value of the user-defined measurement range (corresponding sub index value of object 2101h = 1: for user setting).

Properties

Object properties:

Sub index

Description

Data Type

Default

Access

PDO mapping

Backup

0

Sub index number (analog input number)

UNSIGNED8

24

ro (read only)

-

1

Maximum measured value of CH1

INTEGER16

0x7FFF

rw (read-write)

-

...

 

 

 

18

Maximum measured value of the last channel

INTEGER16

0x7FFF

rw (read-write)

-