Double-click the PWMQ instruction to display the following dialog box. In the following dialog box, specify each of the settings.

For details on the special I/O of the LT, refer to the following.
 31.5 Controlling External I/O with LT
31.5 Controlling External I/O with LT

| Setting | Operand | Description | Setting Range | 
|---|---|---|---|
| CH | S1 | Specify the channel number to which the PWM output is assigned. The PWMQ output for the channel number specified here is stopped. (Event occurrence notification to PWM instruction only) | CH1 - CH4 | 
| D1: Instruction Status | D1 | Specify the integer variable for storing the status of instruction execution. As the variable to be specified here, be sure to use the same variable as that for PWM D1: Instruction Status. | Integer variable only |