***************************** GP-Pro EX Ver.4.07 **************************** Sep 2017 Digital Electronics Corporation Preface Thank you for using GP-Pro EX. GP-Pro EX is software to create logic programs and screen data for graphical operation touch panels. The Windows environment ensures operability and high performance. Please visit the Pro-face website (http://www.pro-face.com/) for the latest information. Table of Contents (0) Version (1) New Features List = V4.07.200 ===== 1-1 Support of New Features = V4.07.100 ===== 1-1 Support of New Features = V4.07.000 ===== 1-1 Support of New Features = V4.06.300 ===== 1-1 Support of New Features = V4.06.100 ===== 1-1 Support of New Features = V4.06.000 ===== 1-1 Support of New Features = V4.05.100 ===== 1-1 Support of New Features = V4.05.000 ===== 1-1 Support of New Features = V4.04.000 ===== 1-1 Support of New Features = V4.03.300 ===== 1-1 Support of New Features = V4.03.100 ===== 1-1 Support of New Features = V4.03.000 ===== 1-1 Support of New Features = V4.02.000 ===== 1-1 Support of New Features = V4.01.000 ===== 1-1 Support of New Features = V4.00.000 ===== 1-1 Support of New Features (2) Limitations 2-1 Editor 2-2 Display Unit 2-3 Device/PLC 2-4 WinGP 2-5 Pro-face Remote HMI Server (3) When Serial No. and License Key Code are not input (4) Installation and Uninstallation 4-1 Installation 4-2 Uninstallation (5) User Registration (6) Manuals (7) Fixed Defects = V4.07.200 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.07.101 ===== 7-1 Display Unit = V4.07.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.07.000 ===== 7-1 Installation 7-2 Editor 7-3 Display Unit 7-4 Device/PLC = V4.06.300 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.06.200 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.06.101 ===== 7-1 Installation = V4.06.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.05.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC 7-4 Pro-face Remote HMI Server = V4.05.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.04.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC 7-4 Pro-face Remote HMI Server = V4.04.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.03.400 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.03.300 ===== 7-1 Display Unit = V4.03.200 ===== 7-1 Editor 7-2 Display Unit = V4.03.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.03.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.02.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.01.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.00.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC Contents ================================================================================ (0) Version Editor: Ver.4.07.200 System/Runtime: Ver.4.7.20 Sub-system/OS Core: Ver.4.7.20 (SP5B10, GP4000 series except for GP4000M series, GP41** series) Ver.1.2.7 (LT4000 series) Ver.1.3.4 (GP4000M series) Ver.1.1.3 (GP-4104) Ver.1.3.5 (GP-4105, GP-4106, GP-4107) Ver.3.6.5 (GP3400 series, GP3500 series, GP3600 series, GP3700 series) Ver.3.6.0 (ST3000 series, GP-3200 series, AGP3310HT, AGP3300HS/HL) Ver.3.6.3 (LT-3300 series, AGP3300T/U/S/L, AGP3301S/L) Ver.3.5.1 (Other than above models) Memory Loader: Ver.4.7.20 (1) New Features List = V4.07.200 =================================================================== 1-1 Support of New Feature - EZ LAN Adapter now supports GP4200 Series and GP4300 Series. - SP5000 Series Power Box (SP5B10) now supports I/O driver listed below. - FLEXNETWORK - CANopen = V4.07.100 =================================================================== 1-1 Support of New Feature - EZ LAN Adapter now supports GP4400 Series, GP4500 Series, and GP4600 Series. - Pro-face Connect is now supported. - Newly-added communication driver The following features supported. YASKAWA INFORMATION SYSTEMS MMCloud TCP Client. = V4.07.000 =================================================================== 1-1 Support of New Feature - GP-4G01 is now supported. - SP5000 Series Open Box (SP-5B41) is now supported. - You can now append the date and time to sampling CSV file names. - You can now transfer sampling CSV files to a FTP server. = V4.06.300 =================================================================== 1-1 Support of New Features - DC Power Supply Adapter for SP5000 Series Open Box is now supported. - External PLC simulator now supports GX-Works2/GX-Works3. - Function version upgraded communication driver The following features supported - Siemens AG TIA Portal Ethernet - The following settings were added - SP5000 Series - GP4000 Series - GP4100 Series(GP4114) -PROFIBUS International PROFIBUS DP Slave - SP5000 Series(SP-5B10) -OMRON Corporation CS/CJ/NJ Series EtherNet/IP - Tag search - Remove array item number zero limitation - Support LREAL Tag type (Convert to 32 bits Float type) (Only NJ Series) -YASKAWA Electric Corporation INVERTER/SERVO SIO - Support GA700 Series -YASKAWA Electric Corporation MP Ethernet/MECHATROLINK - Support Sigma-7C - KEYENCE Corporation KV-700/1000/3000/5000 Ethernet - Expand MR device address(Max MR999 to MR3999) for KV-7500 CPU. - Mitsubishi Electric Corporation iQ-R/F Ethernet(SLMP Client) - Passed CC-Link Certification - Support iQ-R New CPU - Support other station access command - Changed driver name (Added [SLMP Client]) - WinGP now supports Windows 10. = V4.06.100 =================================================================== 1-1 Support of New Features - SP5000 Series Open Box (SP5B40) now supports the following display modules: - SP-5600TP SVGA (800*600) - SP-5660TP SVGA (800*600) - SP-5700TP SVGA (800*600) - SP5000 Series Power Box (SP-5B10) now supports display modules with 9-point calibration settings. - The [Do not transfer all if no change in project] option is now available in the [Save as] dialog box. - You can now use system variables to check the recipe label of enhanced recipes. - You can now edit a display unit's [Ethernet] settings from the Transfer Tool. - You can now use system variables to check the project file name. = V4.06.000 =================================================================== 1-1 Support of New Features - GP-4311HT is now supported. = V4.05.100 =================================================================== 1-1 Support of New Features - On the Open Box, you can now use WinGP to check the status of the operating system's Enhanced Writer Filter (EWF). = V4.05.000 =================================================================== 1-1 Support of New Features - The following 3 models are now supported. - GP-4114T - GP-4115T - GP-4116T - You can now use the device/PLC to change screens on Remote HMI (client) set to asynchronous mode. - Function version upgraded communication driver - Mitsubishi Electric Corporation iQ-R/F Ethernet - Pass-Through function supported. - YASKAWA Electric Corporation MP Ethernet/MECHATROLINK Driver - The driver name changed from "MP/INVERTER/SERVO Ethernet" to "MP Ethernet/MECHATROLINK". - R7G4HML3-LC2 of M-System Co., Ltd now supported. - K1G of Azbil Corporation now supported. - Cognex Corporation In-Sight Vision Systems - In-Sight 7000 now supported. - KEYENCE Corporation KV-700/1000/3000/5000 CPU Direct - KV-7000/KV-Nano Series now supported. - KEYENCE Corporation KV-700/1000/3000/5000 Ethernet - KV-7000/KV-Nano Series now supported. - PS-5000, PS/PE-4*00 series and PC/AT now support portrait orientation. - The following products now run on Windows 10. - GP-Pro EX (screen editor) - Transfer Tool - Version Reverter - Project Comparison Tool - Project Converter - Recovery Tool - Pass-Through - Device Data Copy Tool - Pro-face Remote HMI Server - GP-Viewer EX = V4.04.000 =================================================================== 1-1 Support of New Features - WinGP now supports True Colors for Image and JPEG files. - WinGP now supports high resolution for PS-5000, PS/PE-4*00 series and PC/AT. - The Project Converter now supports LT3300T. - You can now enter the GP-Viewer EX key code from the Transfer Tool. - WinGP now supports PS-5000 series. - WinGP SDK now runs on Microsoft .Net Framework 4.0. - Newly-added communication driver - Mitsubishi Electric Corporation iQ-R/F Ethernet - Panasonic Industrial Devices SUNX MEWTOCOL7-COM Ethernet - Function version upgraded communication driver - ODVA EtherNet/IP Explicit Messaging - Custom Explicit now supports "Get Attribute Single" Service (0x0e) and "Set Attribute Single" Service (0x10). - Azbil Corporation Controller (CPL) - Burner Controller BC-R series now supported. - Mitsubishi Electric Corporation Q/QnA Series Ethernet - High-Speed Universal Model (QnUDVCPU) now supported. - Mitsubishi Electric Corporation Q Series QnU CPU Ethernet - High-Speed Universal Model (QnUDVCPU) now supported. - Rockwell Automation, Inc. EtherNet/IP - When automatic port number allocation is enabled, you can now configure Individual Device Settings to one physical target PLC for both the "ControlLogix/CompactLogix Series" and "Control/Compact/Flex Logix Series Native". - JTEKT Corporation TOYOPUC CMP-LINK SIO - PC10G-CPU now supported. - PC3JG-CPU's EB device now supported. - JTEKT Corporation TOYOPUC CMP-LINK Ethernet - PC3JG-CPU's EB device now supported. - Relay communication now supported. - Azbil Corporation MODBUS SIO Master - Series name change from KG to K1G. - Beckhoff Automation GmbH TwinCAT ADS/AMS - AMS NetID setting now supported in offline mode. - Pass-Through Function Setting Tool - Timeout setting now supported. - Mitsubishi Electric Corporation iQ-R/F Ethernet - Label import function now supported (iQ-R series only). - Panasonic IndustrialDevices SUNX FP Series Computer Link SIO - Change in maker name. Panasonic Electric Works SUNX Co., Ltd. -> Panasonic Industrial Devices SUNX - Seiko Epson Corporation Remote Ethernet - A new device now supported. - Siemens AG SIMATIC S7 MPI Direct - Tag import dialog box now improved. - Siemens AG SIMATIC S7 Ethernet - Tag import dialog box now improved. = V4.03.300 =================================================================== 1-1 Support of New Features - GP4000 series (except for GP4100 series, GP-4201TM and GP-4301TM) supported compatible parts for stable service. = V4.03.100 =================================================================== 1-1 Support of New Features - You can now expand the user screen area in AGP-3560T. = V4.03.000 =================================================================== 1-1 Support of New Features - You can now check search results from a recipe list part by using system variables. - You can now use a system variable to copy, save, and reload recipes. - You can now receive recipe labels. - The File Manager can now use the Remove DEL Key feature with CF/SD cards. - Pro-face Remote HMI is now available in WinGP. - Pro-face Remote HMI now supports multiple client connections. - Function version upgraded communication driver - OMRON Corporation CS/CJ/NJ Series EtherNet/IP - Added support for double-byte characters on the NJ series. - YASKAWA Electric Corporation MP/INVERTER/SERVO Ethernet - Sigma-7 series is supported. = V4.02.000 =================================================================== 1-1 Support of New Features - In the Common Settings, you can now set up [No timeout] for the timeout time. - In the Common Settings, you can now set up [No timeout] for the timeout time. - When communication is unstable, you can now define a timer for terminating the connection. - When using the Start application command, you now have the option to suppress WinGP CPU usage. - Function version upgraded communication driver - ODVA EtherNet/IP Explicit Messaging - Implicit messaging now supported. - Custom Explicit message now supported. - TOSHIBA MACHINE Co., Ltd. TC Series(TCmini/TC200) Device Data Copy Tool - Now supports VGA display. - YASKAWA Electric Corporation MEMOBUS Ethernet Device Data Copy Tool - Added support for new transfer files. (Maintenance Monitor Setting, FTP Client definition.) - The following products now run on Windows 8.1. - GP-Pro EX (screen editor) - Transfer Tool - Version Reverter - Project Comparison Tool - Project Converter - Recovery Tool - Pass-Through - WinGP - WinGP SDK - Device Data Copy Tool - Open Box (SP5B40) models now support portrait orientation. - The following now support VGA display: - SP5000 series (Box Module) - SP-5B10 (Display Module) - SP-5500TP - SP-5600TP - SP-5660TP - SP-5700TP = V4.01.000 =================================================================== 1-1 Support of New Features - You can now import the recipe data of enhanced recipes. - Importing/exporting enhanced recipes You can now import and export element labels and recipe labels. - Enhanced recipe search You can now use system variables to search for enhanced recipes. - Mapped address You can now edit enhanced recipe element values on the device/PLC. - Send options When transferring an enhanced recipe to a device/PLC, you can write the enhanced recipe's label and ID to the defined address. - Function version upgraded communication driver - Beckhoff Automation GmbH TwinCAT ADS/AMS - Support TwinCAT3. - Reading a large number of array elements has been optimized. = V4.00.000 =================================================================== 1-1 Support of New Features - The following models are now supported: - GP-4000M (Rear Modular Type) - SP5000 series (Box Module) - SP-5B10 - SP-5B40 (Display Module) - SP-5400WA WVGA(800*480) - SP-5500WA WXGA(1280*800) - SP-5500TP SVGA(800*600) - SP-5600TP XGA(1024*768) - SP-5660TP XGA(1024*768) - SP-5600WA WXGA(1280*800) - SP-5700TP XGA(1024*768) - Pro-face Remote HMI Server function is now supported. - Pro-face Remote HMI function is now supported on the SP5000 Series. - Pro-face Remote HMI function is now supported on the GP-4000M Series. - Server list screen now supports monitoring triggered alarms. - You can now create a project using [Create Project From Configuration File (Pro-face Device Configurator)]. - Newly-added communication driver - CoDeSys Automation Alliance CoDeSys Ethernet - CoDeSys Automation Alliance CoDeSys SIO - Control Techniques MODBUS SIO Master - Control Techniques MODBUS TCP Master - IEC Standard IEC 60870-5-101 - Siemens AG Ethernet Gateway MPI/PROFIBUS - Function version upgraded communication driver - Mitsubishi Electric Corporation FX Series CPU Direct The following setting was added: FX3S Series is supported. (2) Limitations 2-1 Editor - If you use many image fonts, it may take longer to open projects, change registered characters for the image font, and edit text. - #H_ScanOffControl does not appear in the Address and Cross Reference windows. - When the screen editor language setting and the font set do not match, pasting of parts may not work with the Cut and Paste commands. When that happens, use the Copy and Paste commands. - If you use the version reverter on a project set up with a sampling group associated with consecutive addresses and sampling words of 2 or more, the project may not be converted or the sampling settings may be deleted. - If you draw an XY Historical Trend Graph or XY Data Block Graph on base screen 9000 or higher, the graph display area will not appear on the display unit nor in simulation. - Comparison result of [Device/PLC settings] may appear as "Different" though project files have same [Device/PLC] Settings. 2-2 Display Unit (Runtime) - When a USB device is inserted/removed, all USB devices may not become disabled under the condition that five or more USB devices are connected at the same time using the USB HUB in GP-4000 series. If this phenomenon occurs, reset the Display. - When two or more Data Displays with "Indirect" specified are made to be invisible at the same time while displaying a pop-up keypad, some Data Display may not be invisible. - A keypad is closed while the [Alt] key on the keypad of the RPA Window Display is held down. When the keypad is opened next time, the [Alt] key remains held down. - Do not use a logic program during communication with a Device/PLC using a USB/SIO (RS422/485). If the logic program is used in the situation, a communication error may occur. - If you set an integer operand for an OUT instruction, and you use the online monitor to forcibly pass power, logic may not operate properly. - In GP4000 series (except for GP-4100 series) and LT4000 series, the buzzer sound in Ver. 3.5 is different from that in Ver. lower than 3.5. - While logic is stopped on the GP-4G01, if you press and hold down both the [USB1] and [SD] removal switches at the same time, the [PWR] LED lights start flashing irregularly. - Do not attach/detach the fingerprint authentication unit while turning on the power to the Display. Doing so, inconsistency occurs between the security data and the fingerprint data and the display of the authentication and the password setting may not operate normally. If an inconsistency occurs between them due to attachment/detachment of the fingerprint authentication unit, update the fingerprint data of the fingerprint authentication unit using the "Update DB" function. - Do not attach/detach the transfer cable while transferring to the SP5000 Series Open Box (SP-5B40). Even if the cable is detached, the unit will not detect an error. - On the Power Box(SP-5B10) of the SP5000 series, In the case of forced transfer mode, you cannot transfer using LAN2. - If the project is large and many functions are set up, the display unit may restart repeatedly after transfer. - If change models of project data to SP5000 Series Open Box, screen transfer may not be able to transfer. - Compared to other series, the buzzer for the Open Box's (SP-5B40) Bit Momentary switch sounds different. - The Windows task bar flickers if you continually trigger the system menu's display operation (simultaneously touch the top-right and bottom-left corners) on the SP5000 series Open Box (SP-5B40). - On models that support 2-point touch, while the first touch is initiated and you work with the system menu, system menu operations may not work. Display the system menu again and menu operations become available. - On the SP5000 series Open Box (SP-5B40), even though there are no devices connected, in the offline menu, the Peripheral Settings screen's USB Screen shows USB equipment. - On the GP4200 Series, GP4300 Series, and LT4000 Series, you cannot edit Web Server settings offline. - With the SP5000 Series Power Box (SP-5B10) and WinGP, do not touch the top-right or top-left corners while starting up. While normally this would take you to offline mode, there are certain circumstances when this will not work. - On the GP-4100 Series (Color Model), if you download the different CML file in a row without ending the memory loader, SRAM may be initialized after restarting the display unit. - When the [Compress] check box is selected, transparency may not display properly. - Search results may not display if you use system variables to search for a recipe, while deleting a recipe in an Enhanced Recipe List part. When this occurs, reset the display unit. - When there are a large number of recipes, importing recipes may take considerably longer than it did in Ver.4.6.10. - On the display unit, you can add enhanced recipe data to a project even if it exceeds 100% of its maximum transfer size. On the editor, if you use the Receive Project command to get the project from the display unit, you may not be able to transfer the project back to the display unit due to a transfer size error. - If you set up a variable with less than 32 words as the label's destination address, the enhanced recipe may not work properly. - When [Display Unit] - [Operation] - [Output to External Buzzer Terminal] is enabled on the GP3300H or GP4000H series, the GP3000H conversion adapter emits the external buzzer for the following operations from the maintenance menu. - Check Pattern - Check Touch Panel - Calibrate Touch Panel - Check COM1/COM2/LAN - Memory Info - Check Function Switch - When the operation switch is enabled on the GP4000H series, only monitoring is possible from the client. The client cannot perform any operations. - Occasionally the File Manager does not sort its operation log's output files in file creation order. - In the destination, if you specify a FTP server with PASV disabled, file write may fail and a 0-byte sized file may be created in the destination folder. - When using GP4000M or LT4000M Series, restarting the display unit will erase the Japanese FEP information. - When using SiteManager Embedded V6121 17033: The Transfer Tool, GP-Viewer EX, Pro-Server EX, and Pro-face Remote HMI Client for Win's automatic search feature may not detect display units on the network. - With SiteManager Embedded V6121 17033, you can use only ASCII text for the Proxy Password. - With SiteManager Embedded V6121 17033, in the offline screen's Site Manager Embedded settings, when the LAN cable is disconnected from the display unit, a maximum 180 seconds may elapse before the status display shows as disconnected. To change the time it takes before the status display is updated, change the GateManager's Heartbeat Interval and Keep-Alive Interval values. Additionally, set the Heartbeat Interval so that it is greater than the Keep-Alive Interval. - When connecting multiple SiteManager Extend and LinkManager to an Open Box set up with SiteManager, Pro-Server EX may not operate properly on some of the LinkManager. - Sending or receiving large projects via LinkManager fails sometimes. - If LinkManager is already installed and you install LinkManager again, sometimes the existing shortcut is not deleted and results in duplicate shortcuts. - If you forcibly transfer via Link Manager a project to a display unit set up as the agent of Site Manager Extend, the transfer operation sometimes fails. - Turning on the display unit with the SD card inserted, it may take a few seconds longer to show the initial screen. 2-3 Device/PLC - In Pro-Server EX's Device Monitor function when a Multiple Bit Write operation is performed on an array type Tag it may not write correctly. - When single bit write operation is performed on a 32-bit Tag(DINT), the 16th bit cannot be written. - When a Copy / Paste operation which results in the maximum number of Tags being exceeded no error is displayed. - When several Tag Data Files are created, the maximum number of Tags may not be checked correctly. - In Pro-Server EX's Device Monitor function the Multiple Bit Write operation may not work in some cases. - Do not use "Indirect" setting for the String type. If it is specified, data may not be displayed normally. - When STRING variables are displayed in Device Monitor of Pro-Server EX, only two characters are displayed. - Some spelling mistakes are found in English error messages. - If an error occurs during communication, set "1" or larger value for Retry Count. - When a bit device is specified in Alarm Summary, alarms of 17th bit or later are not displayed normally. If this phenomenon occurs, use the word device. - When the link parameter device is read, the communication cycle time becomes an illegal value. - In a screen where a Display Unit does not communicate with a PLC: When an access is made to the PLC using the pass-through function after the PLC is restarted, the password lock occurs to the PLC. Make connections using the pass-through function after the screen is shifted to the one where the Display Unit communicates with the PLC. - Do not write the data including the bit address with the extended recipe function. If such writing is made, a communication error may occur. - Do not input 32 or more characters for the device address in Address Input of Device Monitor. - Tag information allocated to I/O units may not be imported normally. If this phenomenon occurs, edit the data with the Editor manually. - When bit read/write for two or more points is performed to a bit-accessible word device or word type tag, an address other than the specified address may be read/written. - When Gateway Mode on the GP-4G01, occasionally a response error occurs on the HMI. - The pass-through function cannot be used when WinGP and IIS FTP servers are used at the same time. 2-4 WinGP - The buzzer of WinGP does not sound in PS-4700 (Z510). - When the File Manager displays a folder path and data in that folder is updated, the folder path reverts to the default path. - The system load status or wireless communication status may prevent the application from disconnecting within the time specified by the property: Disconnect after communication is down for. - When using the USB transfer cable (CA3-USBCB-01) to get display unit information, the screen list may not be available. You can add a base screen to make the screen list visible. - When using Window 7 or later as the operating system, you cannot remove hardware while offline. When detaching a storage device from this product, use the Windows Safely Remove Hardware tool. 2-5 Pro-face Remote HMI Server - In Windows 8 / 8.1 / 10, application distribution fails to correctly display distributed screens of Excel 2013 on the client. To distribute Excel 2013 screens, use desktop distribution. (3) When Serial No. and License Key Code are not input - Project data cannot be transferred to the operation panels (except for GP4100 series, IPCs and PC-ATs (Used WinGP)). - Transfer using the Transfer Tool is not available for WinGP. However, using ProjectCopy, you can copy screen data and get it to work. To use ProjectCopy, click [Start]-[All Programs]-[Pro-face]-[WinGP]- [ProjectCopy] on the Windows desktop screen. However, note that ProjectCopy cannot be used in the following cases: - When system data has not been transferred - When system data has been changed WinGP automatically stops after three hours of continuous operation. * It is possible to input the serial No. and the license key code after installation of the software. Start the product and go to [Help]-[Enter Key Code]. (4) Installation and Uninstallation 4-1 Installation - Be sure to quit all application programs and close (disable) all resident programs such as virus detection software before installing the software. - Install this software using a user account with Administrator privileges. - Refer to our support site "Otasuke Pro!" (http://www.pro-face.com/otasuke/) for the operating environment. - By inserting a disk into the DVD drive, Setup window will appear. If the Setup window does not appear, click the desktop's [Start] button and then click [Run]. In the text input field, enter [D:\ProEX_Setup.exe] and click [OK]. (As for the "D:\" part, enter your DVD drive name.) * Some of the tools require a license. In cases below, USB transfer cables may not be recognized correctly: - When you installed the software with a USB transfer cable connected - When you started using the software without restarting your computer - 1)Insert the Windows installation media. If you do not have the Windows installation media, contact the PC manufacturer. 2)Select "Open command prompt as administrator" on the Explorer. 3)Execute the following command at the Command Prompt. Dism /online /enable-feature /featurename:NetFx3 /All /Source:x:\sources \sxs /LimitAccess *) For x:, specify the drive letter of Windows installation media or the DVD drive. 4-2 Uninstallation To uninstall the software, click on [Start], then select [All Programs]- [Pro-face]-[***], and execute [Uninstall]. ("***" represents the product name and version.) Project files and files in your package files will not be removed by this operation. Delete other tools from [Start]-[Control Panel]- [Add or Remove Programs]. (5) User Registration Please register your software to help us offer enhanced customer support. Since you can confirm the registered information at anytime once you register, you do not have to worry even if you lose it. To register, insert a DVD into the DVD drive, select the User Registration menu in the Set Up Menu screen and complete the online Software User Registration. You can also register after installation by starting the product and registering from [Help]-[Online User Registration]. (6) Manuals To view PDF manuals, the Adobe Reader software must be installed on your computer. Start the product and select [Manual] from the [Help(H)] menu. To view only the manuals, select [Start]-[All Programs]-[Pro-face]-[***] -[Manual].("***" represents the product name and version.) Some manuals need to be downloaded from our support site "Otasuke Pro!". (7) Fixed Defects = V4.07.200 =================================================================== 7-1 Editor - When changing the model for a LT series project, if the I/O driver's L system variable was used in a part, sometimes the system variable's argument did not get updated. - Even though the operating language was Japanese, sometimes part of the sampling settings and global trigger settings displayed in English. - If you ran the Project Converter on a project set up with a Text Table, sometimes the resulting project could not be compared. - If you compare projects where symbol variables were added in a different order, sometimes the comparison will show differences in the symbol variable settings. - Comparing function switches sometimes resulted in the message, "Comparison item not found". - When converting a GP-ProPBIII project of a portrait view model, sometimes the placement of image objects would get re-arranged. 7-2 Display Unit - If the GP is shutdown while an alarm is triggered, on the rare occasion the alarm time stamp showed "00/00/00". - If the GP is shutdown while an alarm is triggered, and a new alarm is triggered after restarting, on the rare occasion the GP stopped working. - On the GP3000 series (excluding the GP-3200 series), using security settings sometimes slowed the scanning of parts. - If you were unable to save Enhanced recipe elements, it occasionally resulted in not being able to run the Enhanced recipe process. - If you used Enhanced recipes on a project whose size approached 100%, by adding enhanced recipe data on the unit you could save beyond the maximum project size. If you transfer it back to the editor and open the project, you may not be able to transfer it again due to a transfer size error. - On the GP4000M series, sometimes the loading of the text table file (USB memory) on start up did not work. - With the combination of GP-Pro EX V4.07.100 and SP5000 series (SP5B10) or GP4000 series (excluding GP-4100 series), sometimes you could not use a SD card on the Memory Loader tool. - With the combination of GP-Pro EX V4.07.100 and SP5000 series (SP5B10) or SP5000WA series, sometimes the initial screen displayed without recognizing USB storage even though the initial screen was set up to display only after recognizing USB storage. - With the combination of GP-Pro EX V4.07.100 and SP5000 series (SP5B10) or GP4000 series (excluding GP4000M series, GP41** series), frequently accessing the SD card on the display unit, sometimes the screen update stopped. - Connecting GP-Viewer EX to WinGP and operating an Historical Trend Graph caused the display of an error dialog box. - When communicating at high speed (115.2 kbps) with a PLC with good communication performance, occasionally a communication error occurred on the HOST side. 7-3 Device/PLC - On the LT4000 series, GP-4402 WW, GP-4502WW, GP-4114T, GP-4115T, GP-4116T, and SP5B10, sometimes after transferring an error displayed and the unit did not start up. - Note the following fixed defects when Gateway Mode on the GP-4G01: - If the GP-4G01 has never run communication at all and the HMI starts communication, a response error occurred once on the HMI. After a re-transmission, the error is restored. - If you enter the GP-4G01 offline screen then change back to the online screen, a response error occurred on the HMI. = V4.07.101 =================================================================== 7-1 Display Unit - With the combination of GP-Pro EX V4.07.100 and SP5000 series (SP5B10) or GP4000 series (excluding GP4000M series, GP41** series), frequently accessing the SD card on the display unit, sometimes the screen update stopped. = V4.07.100 =================================================================== 7-1 Editor - If you use Call Screen to load a screen with text that used the Image font type with Anti-alias enabled, sometimes the text defined in the screen editor did not appear. - Improved the issue that logic tab in simulation not displaying. - Entering invalid characters in the Project Comparison Tool's Source/Target for comparison fields, or the Version Reverter's Convert From File or Convert To File fields, sometimes caused the tool to exit unexpectedly. 7-2 Display Unit - If you set the Retry Count to 9 or more in the Monitor settings, sometimes the connection failed and an error occurred. - Failing to transfer a project with device/PLC registers mapped to the System Data Area sometimes caused an invalid value to get written to the system area start address. - Sometimes GP4000 Series units could not register fingerprints on EZ Fingerprint Recognition Units sold from 2016 onward. - Added preventative measures against spoofed arbitrary code that may be executed. - On the GP-4201TW, the USB port (Type A) could not be recognized. 7-3 Device/PLC - When converting the project of GP-Pro PBIII which set the following communication driver, it could not be transmitted to the HMI. - Fanuc LTD. Power Mate Series - Fuji Electric Co.,Ltd. MICREX-SX Series SIO - Hitachi, Ltd.S10 Series SIO - KEYENCE Corporation KV-700/1000/3000/5000 CPU Direct - KEYENCE Corporation S10 Series SIO - Mitsubishi Electric Corporation A Series CPU Direct - Mitsubishi Electric Corporation A Series Computer Link - Mitsubishi Electric Corporation FX Series Computer LinkA - Mitsubishi Electric Corporation FX Series CPU Direct - Mitsubishi Electric CorporationQ Series CPU Direct - Mitsubishi Electric Corporation Q/QnA Serial Communication - Mitsubishi Electric Corporation QnA Series CPU Direct - OMRON Corporation C/CV Series HOST Link - OMRON Corporation CS/CJ Series HOST Link - Panasonic IndustrialDevices SUNX FP Series Computer Link SIO - Siemens AG SIMATIC S5 3964(R) - Siemens AG SIMATIC S7 3964(R)/RK512 - TOSHIBA MACHINE Co., Ltd. TC Series(TCmini/TC200) - YASKAWA Electric Corporation MEMOBUS SIO - YOKOGAWA Electric Corporation Personal Computer Link SIO = V4.07.000 =================================================================== 7-1 Installation - If you uninstall Remote HMI Server then re-install without restarting your computer, installation could fail. - If you ran a software update while Pro-face Remote HMI Server is running, installation could fail. 7-2 Editor - When the display unit was set up with a Send/Receive project password and on connection you entered the wrong password, when the password screen opened again an error message appeared. - When checking the Memory Loader backup data or creating a new project, the file selection screen's file pulldown list contracted right away. 7-3 Display Unit - WinGP failed to start on computers with the Multilingual User Interface (MUI) pack installed. - In Forced Transfer mode, on exiting WinGP a dialog box appeared with corrupted characters in the title bar. - If you set an invalid value other than a BCD value for the clock data, the clock did not show the time correctly. - When the device/PLC communication scan was OFF, an error appeared when accessing the PLC. - When the transmission speed was 115,200 bps, the USB-Serial (RS-232C) conversion cable could not be recognized. - Sometimes sampled data could not be collected anymore if you detached external storage from the unit while saving sampled data to CSV format. - While an FTP server was not added in the FTP server settings and you captured a screen and tried saving to an FTP server, you could not enter offline mode or transfer mode anymore. - If you set an invalid value for the Device View's Update Frequency parameter from an URL, the device value did not update or an error occurred. - After setting the label's destination address in the screen editor, if you change the destination address by using either Change Device/PLC or Convert Address, sometimes the recipe label did not display. - Entering offline mode while running one of the following processes sometimes caused the corresponding operation to not run: - [Save] in the Save GP Screen tool - [GP JPEG Upload] action - Excel form action's [Upload GP screen data] - When an online error and system error occur at the same time, sometime touch did not work and the error window's reset button would not operate. - There was an issue where system errors did not display on the GP-4201TM (Modular Type) and GP-4301TM (Modular Type). 7-4 Device/PLC - The use of Ethernet 2 port functionality by SP5000 series (SP-5B10) could result in communication errors. - Cannot launch HMI if project file imported several Tag data in some case. = V4.06.300 =================================================================== 7-1 Editor - In simulation, when monitoring the logic, the display position of I/O values may shift sometimes. - When comparing projects with the [Show only differences] option, double-clicking the difference sometimes displayed the wrong line. - Addressed the feature in our software that caused some antivirus software to erroneously identify as a virus. 7-2 Display Unit - When using GP4000H (hand-held) Series and you connect to multiple USB hubs and USB devices, the display unit sometimes reset on disconnecting an USB device. - Turning ON #H_RecipeControlMapAddress occasionally generated a system error. - The wrong warning message appeared when drawing an alarm part with banner enabled and a part with animation enabled on the same screen. - When using SP5000 or GP4000 Series (except GP-4100 Series), using a read-only SD card sometimes slowed the performance of operation logs. - When using SP5000 or GP4000 Series with USB 2.0 USB memory, the Memory Loader sometimes failed. - Memory Loader could not start under the following conditions. - Display unit's system version was 4.50.000 or later - Startup data for the Memory Loader was created on version before 4.50.000. - When using GP3000 and LT3000 Series units, the wrong value was set to #L_FaultLogicScreen and #L_FaultStep. - When using SP5000 Series Open Box (SP-5B40) and while WinGP was restarting after a transfer, or on exiting WinGP, the EZ Tower Light sometimes buzzed and all the layers turned red and flashed. - When using the Load Text Table feature with codepage 850, sometimes the text did not display properly. 7-3 Device/PLC - Grouped Data blocks and PLC tags cannot be imported. - Transfer error is happened if user configured assembly instance over 256. - Individual Device Settings in Beckoff TwinCAT driver sometimes shows wrong settings. = V4.06.200 =================================================================== 7-1 Editor - In the Text Table Settings, when the value in the Change Language control address is out of range (17 or greater), editing the label in an extended recipe could cause simulation to exit unexpectedly. - Using unregistered variables in the function block of a logic program occasionally caused simulation to exit unexpectedly. - Occasionally simulation stopped working when you assigned a fractional value to a Float or Real data type variable. 7-2 Display Unit - Occasionally this tool was unable to copy projects associated with PS-5000 or PS/PE-4000 models to WinGP. - Occasionally, the SP500 Series Power Box (SP-5B10) did not communicate properly over the COM port. - An USB device with three or more configuration descriptors becomes unusable when connected to the GP4000 Series (except GP-4100 Series, GP-4201-TM, and GP-4301TM). - Occasionally, the SP500 Series Power Box (SP-5B10) did not communicate properly over the USB/SIO(RS232C) and USB/SIO(RS422/485) cables. - Occasionally, the SP500 Series Power Box (SP-5B10) did not accept input from a USB bar code reader properly. - When using the SP5000 Series Power Box (SP-5B10) with the Advanced Display (SP-5x00WA), occasionally touch panel operations did not work properly. - On the GP-4100 Series (color model), after using a Special Switch to transfer filing data from the device/PLC to SRAM and the display unit was turned OFF, occasionally the transferred data was not saved. - When you setup the System Data Area as a PLC device, and you save sampling data in CSV format, occasionally the timestamp for sampling data is shown as 00:00:00. - In rare cases, using drawing functions in extended scripts caused the display unit to stop working. - On the LT4000 Series, after the PLSQ instruction you could not output acceleration/deceleration pulses from the PLSY instruction only. - When you start Monitor Step on the SP5000 Series Power Box (SP-5B10), the value in a portion of the bit variables used in function blocks could not be refreshed. - Even when communication is not yet established with a PLC once, now you can still back up internal devices.